Tender For tender for prov. sop to jal shakti vibhag to lwss scheme at nagni mata mandir in village gangath proposed 11/0.4kv 250kva sub-station along with ct-pt unit at village gangath in (e ) sec. gangath (u) esd gangath.sub head:-estimate for r/r of damaged 11/0.4kv,100kva s/stn dhangupper due to land slide occurred in (e) sec. dhangupeer (u) esd damtal
Tender For corrigendum : supply and installation of abt meter with metering cabinet and construction of structures and foundation at 132kv sending end (panchgram gss) and receiving end (star cement campus),132kv ct and pt (o/d) and other materials for star cement ne ltd
Tender For corrigendum : estimate for prov and fixing of ct-pt combined unit for various jsv scheme in electrical section mandap uesd hpsebl dharampur.
Tender For replacement of damaged 33kv, 3-phase, 50hz outdoor type onan cooled ct-pt combined metering unit along with other allied works at wss tangnar stage 2nd
Tender For corrigendum : for supply of 11 and 33 kv metering equipments (oil immersed combined ct pt units) of assorted ratings/ratios and accuracy class of 0.5s for ht metering - 11 kv outdoor pole mounting type oil immersed 0.5s accuracy class combined ct:pt (metering) units conforming to is:2705:1992, is:3156: 1992 with latest amendment & technical specification attached in following ct ratios:, 11kv, 7.5/5 amp me, 11kv, 15/5 amp me, 11kv, 25/5 amp me, 33 kv outdoor pole mounting type oil immersed 0.5s accuracy class combined ct:pt (metering) units conforming to is:2705:1992, is:3156: 1992 with latest amendment & technical specification attached in following ct ratios:, 33kv, 10/5 amp me, 33kv, 20/5 amp me, 33kv, 30/5 amp me, 33kv, 50/5 amp me, 33kv, 100/5 amp me, 33kv, 200/5 amp me
Tender For n.i.t. for job work for wiring and testing of 132kv ct & pt at 132kv mrss sp-iii, nmdc kirandul and 132kv mrss nmdc spl project baccheli under ee(mrt) dn. csptcl, jagdalpur.
Tender For day to day running electrical maintenance of 33kv switchyard 33kv ct pt 33kv mocb 33kv control panel 11kv vcb 11kv switch gear ngr sf6 cable control panel main regional sub station mrss under g m unit dhori area for a period of two years
Tender For supply of 11kv and 33 kv outdoor oil cooled metering unit (combined ct and pt set) under south andaman division sub-division - supply of 11kv & 33 kv outdoor oil cooled metering unit (combined ct & pt set) under south andaman division sub-division., 11kv outdoor oil cooled ctpt combined unit 50hz three phase six bushing typewith three no. ct and one no. three phase vtwith hv neutral broughtout andearthed ilv 12/28/75 kvp ins class a, ref std refstd is16227- 1&4ct specification:ratio 80-40/5a class 0.5 burden 15va isf=7.5@ 40a stc 4ka time: 1 sec.vt specification:ratio 11kv/110v class 0.5 burden 100va voltagefactor 1.2 continuous/1.5 for 30 seconds vectorgroup/connection star/star (ynyn0). terminals: brass stud typeprimary terminals m12 in size with nut, plainwasher, spring washer & check nut. withoutterminal connector. minimum creepage distance25mm/kv.note :primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50hz three phase six bushing type with three nosct and single nos three phase vt with hvneutral brought out and earthed ilv 36/70/170 kvpins class a ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4ka time :1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 secondsvector group/connection star/star (ynyn0).terminals:terminals: brass stud type primary terminalsm12 with nut, plain washer, spring washer &check nut. without terminal connector. minimumcreepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50hz three phase three bushing three nos. ctsand one no. three phase vt with hv neutralbroughtout and earthed. ilv 36/70/170 kvp insclass a , ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4 ka time : 1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 seconds.vector group/connection star/starterminals:brass stud type primary terminals m12 with nut,plain washer, spring washer & check nut.without terminal connector.minimum creepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50 hz three phase three bushing three nos. ctsand one no. three phase vt with hv neutralbroughtout and earthed. ilv 36/70/170 kvp insclass a , ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4 ka time : 1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 seconds.vector group/connection star/starterminals:brass stud type primary terminals m12 with nut,plain washer, spring washer & check nut.without terminal connector.minimum creepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., transportation, transit,insurance, packagingcharges
Tender For cwek/token-122/874 ews/2025-26 repair/ maint of vcbs/ct/pt meters, power transformers and ht feeders and voltage stablizers, street/security light and timer panels at various garrisons in the aor of age e/m under ge 874 ews